CB Series
|
AAON CB Series Condensers & Condensing Units are engineered to be energy efficient, long lasting, and easy to install. standard features include variable speed ecm driven condenser fans, two step compressors, and a continuous fin condenser coil with louvered coil guard. CB Series Condensing Units can be used in residential and commercial application, matching with aaon air handling units. | |
|
|
| |
 |
| |
| Applications |
| • |
Air-cooled condensing unit or a remote air-cooled condenser, from 2-5 tons or 24-60 MBH. |
| • |
Available as an air-source, water-source or geothermal heat pump. |
| • |
Two step scroll compressor, 67% and 100% capacity, includes rubber isolation mounts to minimize vibration. |
| • |
Variable capacity scroll compressor (10-100%) for load matching cooling and improved part load efficiency. |
| |
| |
| |
| Construction |
| • |
Wrap-around, single row condenser coil has no additional rows to trap dirt and debris between and is easier to clean than units with multi-row coils. |
| • |
Louvered condenser coil guards protect the coil from damage and debris. |
| • |
Corrosion resistant polyurethane paint exceeds a 1,000 hour salt spray test - twice the industry standard of 500 hours. |
| • |
Refrigerant circuit contains automatic low pressure and manual reset high pressure safety cut-outs, suction and liquid line Schrader valves, a full charge of refrigerant for up to 25 feet of line set, and a factory provided liquid line filter drier. |
| |
| | |
|
| Fans and Blowers |
| • |
ECM driven condenser fan provides precise airflow control and reduced power consumption while matching each capacity step of the compressor. |
| |
| |
| |
| Control |
| • |
Labeled electrical components and color-coded wiring match the unit specific color-coded wiring diagram which is inside the control compartment. |
| • |
Unit controls are contained within single compartment isolated from the air stream for ease of service and quiet operation. |
| • |
Factory run test report, wiring diagram, and Installation, Operation, and Maintenance manual with startup form are provided in the control compartment of every unit. |
| • |
Optional 24 VAC control circuit transformer to prevent exceeding the capacity of the air handler’s control circuit transformer. |
| |
| |
| |
| Features and Options |
| • |
Split system modulating humidity control is available to provide energy efficient dehumidification, even with low sensible heat loads, without the temperature swings common with on/off reheat systems. |
| • |
High density foam compressor sound suppression blanket to reduce radiated noise. |
| • |
Polymer e-coated coils are available to extend the life of the coils and protect them in corrosive environments. |
| • |
Low ambient fan cycling allows operation down to 35°F for facilities that require mechanical cooling at lower ambient temperatures. |
| |
| | | |
CB Model |
Compressors/ Circuits |
Discharge Direction |
Width |
Height |
Length |
| 024 |
1/1 |
Vertical |
37 |
39 |
31 |
| 036 |
| 048 |
43 |
37 |
| 060 | |
| All dimensions are in inches. |
| |
| |
| |
|